Electrical Resistivity Survey (ERS)

Scientific groundwater exploration, aquifer depth mapping, and 2D resistivity tomography across Pakistan to eliminate dry borehole risks before you drill.

Technical Overview
An Electrical Resistivity Survey (ERS) is a non-destructive geophysical investigation used by Karachi Tubewell & Pumps across Karachi and all provinces of Pakistan to locate groundwater aquifers. Using calibrated Terrameter instrumentation, we identify aquifer depth, thickness, and water quality (fresh versus saline) from depths of 100 feet down to 1,500+ feet. Field tests take 1 to 2 days with formal computer-inverted cross-section reports delivered promptly.
Electrical Resistivity Surveying in the field

Precision Groundwater Detection Technology

Drilling a deep borehole blind without subsurface geophysical data involves massive financial risk. Geological formations across Pakistan feature intricate transitions between impermeable clay barriers, fractured limestone, boulders, and saline coastal intrusion. The Electrical Resistivity Survey (ERS) provides a scientific window into the ground before mobilizing expensive drilling equipment.

By measuring variations in subsurface electrical conductivity, our geophysicists differentiate saturated sand and gravel aquifers from dry bedrock and brackish saline water. Whether planning an industrial tube well in Port Qasim, a farm well in interior Sindh, or a commercial supply in Balochistan, an ERS ensures drilling takes place at the exact coordinate offering maximum water volume and highest water quality.

What Is Included in KTP ERS Investigations

Our geophysical exploration services combine high-precision multi-electrode survey equipment with advanced 2D and 3D computer inversion modeling. Client deliverables include:

Standard Geophysical Deliverables

  • Field reconnaissance & layout planning: Establishing optimum survey traverse orientation to cut across suspected geological faults and strike lines.
  • 1D Vertical Electrical Soundings (VES): Schlumberger array testing to establish detailed vertical stratigraphy and target aquifer depth directly beneath proposed well coordinates.
  • 2D Electrical Resistivity Tomography (ERT): Multi-electrode continuous profiling mapping lateral continuity, fracture systems, and salinity transitions.
  • Raw apparent resistivity curves: Digitally logged voltage and current measurements gathered using high-sensitivity geophysical meters.
  • Computer-inverted resistivity models: True resistivity pseudo-sections processed using robust inversion software to generate colored geological cross-sections.
  • Hydrogeological interpretation: Clear identification of water table depth, aquifer thickness, bedrock contact, and estimated yield potential.
  • Signed drilling recommendation report: Specific borehole depth recommendations, screen placement intervals, and GPS drilling coordinates.

5-Step Geophysical Survey Workflow

Our field engineers execute surveys systematically to prevent surface electrical noise and ensure repeatable data accuracy:

01

Site Inspection & Layout

Our team assesses site dimensions and stakes straight electrode survey lines away from underground metallic pipelines or power lines.

02

Electrode Planting & Coupling

Steel or copper electrodes are driven into the ground at calibrated intervals. Contact resistance is verified with saline wetting where dry soil exists.

03

Controlled Current Injection

Direct electrical current is injected through outer electrodes (A and B) while resultant potential differences are recorded across inner electrodes (M and N).

04

Computer Inversion Analysis

Raw data is imported into 2D/3D inversion software to eliminate topographic effects and calculate true resistivity layer depths.

05

Comprehensive Report & Consultation

We present our hydrogeological findings, mapping freshwater zones, estimating static water levels, and specifying exact drilling depths.

Survey Configuration & Depth Capabilities

The table below summarizes standard survey arrays and depth reach achievable across common Pakistani geological strata:

Survey Array Method Typical Investigation Depth Primary Objective Required Surface Spread Timeline
1D VES (Schlumberger) 150 ft to 1,000+ ft Target borehole depth & sweet/saline boundary 3x target depth 1 - 2 Days
1D VES (Wenner) 50 ft to 400 ft Shallow aquifer & civil soil strata resistivity 3x target depth 1 Day
2D ERT Imaging 100 ft to 600 ft Lateral fault mapping & bedrock profiling Continuous cable roll 2 - 3 Days
Regional Hydrological Mapping Multiple points across site Industrial park or agricultural estate siting Grid layout 3 - 5 Days

Cost Factors for Electrical Resistivity Surveys

Pricing for an ERS investigation is determined by operational requirements rather than generic estimates. Key pricing factors include:

Target Depth

Deeper electrical profiling requires longer electrode spread lines, higher voltage transmitters, and extended data logging time.

Sounding Points

Multi-point 1D sounding grids or continuous 2D tomography profiles provide complete acreage mapping across large commercial estates.

Terrain & Layout

Clear straight-line corridors allow fast testing, while rocky outcrops or urban utilities require special electrode positioning.

Mobilization Distance

Field surveys outside greater Karachi throughout Sindh and Balochistan incorporate crew deployment and logistics.

Price Guidance: Survey rates depend on profile length and required depth penetration. Compared to drilling a dry bore, an ERS represents a fraction of total capital expense.

Field Investigation Case Summary

Field ERS Survey Equipment
Field Survey Example

Aquifer Mapping & Salinity Demarcation

Location: Sindh Industrial Corridor, Thatta & Nooriabad
Investigation Depth: 650 feet VES profiling
Outcome: Detected a 40-foot thick freshwater gravel aquifer layer at 420 feet depth, successfully bypassing upper brackish groundwater lenses.
View Our Client Projects →

Frequently Asked Questions

What is an Electrical Resistivity Survey (ERS)?

An Electrical Resistivity Survey is a non-invasive geophysical testing technique that measures apparent subsurface electrical resistivity by injecting controlled direct electrical current through surface electrodes. The resulting data differentiates between dry rock, clay barriers, saline water, and freshwater-bearing aquifers.

Can an ERS survey tell the difference between sweet and saline water?

Yes. Dissolved salts dramatically lower water resistivity, producing very low ohm-meter readings (typically under 5 to 10 ohm-m). Fresh, potable groundwater displays higher resistivity values (typically 15 to 60+ ohm-m depending on local geology), allowing our geophysicists to differentiate saline layers from drinkable aquifers.

What is the difference between 1D VES and 2D ERT surveys?

1D Vertical Electrical Sounding (VES) investigates resistivity changes directly beneath a central point down to depths of 1,000+ feet, ideal for single borehole siting. 2D Electrical Resistivity Tomography (ERT) captures both vertical and lateral variations across a linear cross-section, revealing fault lines, fracture zones, and aquifer geometry.

How much land area is required to carry out an ERS test?

Because electrode spread determines depth of penetration, exploring down to 500 feet generally requires a straight line span of 1,000 to 1,500 feet for current electrodes. If site space is constrained, our engineers adjust electrode configurations accordingly.

How quickly can KTP deliver the hydrogeological report?

Field acquisition is completed within 1 to 2 days, and inverted computer cross-sections and recommendations are delivered in a formal written report within 3 to 5 business days.

Does an ERS guarantee finding water?

An ERS does not create water, but it dramatically minimizes dry-hole risk. By identifying impermeable bedrock, dry gravel, and saline intrusion prior to rig mobilization, an ERS prevents hundreds of thousands of rupees in futile drilling expenses.

Need an Electrical Resistivity Survey (ERS)?

Contact our geophysicists to evaluate your plot location, determine the survey array, and schedule a field investigation.

Schedule Your Groundwater Resistivity Survey

From deep tube well bore drilling to professional geophysical water surveys, KTP provides robust and trusted solutions across Pakistan.

Call WhatsApp Get Quote